Rhoss UTNR-A Platinum 040÷500 - Установка для рекуперации тепла
UTNR-A Platinum are fresh air terminal units with counterflow opposing flow static heat recovery.
CONSTRUCTION FEATURES
• Recovery unit: very high yield static type with aluminium plates with back-current flows with close step. Extraction of side exchange pack from top or bottom depending on models and versions
• Fans: Outdoor air intake and forward blade dual intake centrifugal exhaust type with a directly coupled electric motor; optionally, EC Brushless technology high efficiency electric motors. The fan unit is installed on anti-vibration mountings to prevent vibrations being transmitted to the structure.
• Structure: frame made with extruded aluminium profile with preloaded nylon joints. Sandwich buffer panels, 23 mm thick, made with galvanised sheet steel on the inside and pre-painted on the outside with thermal and acoustic insulation made of injected polyurethane, with a density of 45 kg/m3.
• Filtering section: filtration sections made of compact cell filters with low pressure drop polypropylene media, removable from the side, with ISO 16890 ePM1 55% efficiency class ( F7 EN 779) in fresh flow and ISO 16890 ePM10 55% ( M5 EN 779) in exhaust flow.
• Factory-installed dirty filter differential pressure switches
• Condensate drain pan made of galvanised sheet steel with condensate drain connection from the bottom.
• Integrated free cooling or thawing by-pass system. Thanks to the presence of a motorised damper next to the heat recovery, a bypass system can be created to manage freecooling or thawing depending on thermo-hygrometric needs or conventions
VERSIONS
• UTNR-A/O PLATINUM - Recovery unit with opposing flow heat exchanger, horizontal installation and with standard multi-speed fans
• UTNRE-A/O PLATINUM - Recovery unit with opposing flow heat exchanger, horizontal installation and with Brushless EC fans that reduce power consumption for ventilation at equal performance.
• UTNR-A/V PLATINUM - Recovery unit with opposing flow heat exchanger, installed vertically and with standard multi-speed fans
• UTNRE-A/V PLATINUM - Recovery unit with opposing flow heat exchanger, installed vertically and with Brushless EC fans that reduce power consumption for ventilation at equal performance.
Available orientation
• 01 - Right-hand connections
• 02 - Left-hand connections
The selected orientation must be specified to process the job order.
Installation
• EXT- Outdoor installation including rain cover, 80 mm-high base and an outdoor electrical box