Lamborghini CaloreClima IDOLA M 3.2 22T-30T - Тепловой насос
This series of air-to-water heat pumps is designed to meet both heating and cooling needs in residential and high-power commercial systems.
All units are suitable for outdoor installation and, thanks to their ability to supply water up to 60°C, they can be used with underfloor heating systems, fan coils, radiators, and for the indirect production of domestic hot water (DHW) via an external storage tank (not included).
The units are equipped with a DC inverter compressor that modulates power output from 30% to 120% of the nominal capacity. They come with a complete hydraulic kit that includes all the essential components for quick and safe installation. These units stand out for their high energy efficiency and low noise levels, making them suitable for use either as the sole heat source or in combination with auxiliary systems such as electric heaters or boilers.
Each unit is supplied with a DHW tank temperature sensor (included as standard, to be installed by the technician) and an outdoor air temperature sensor (pre-installed on the unit), enabling full climate control in both heating and cooling modes.
All units are carefully assembled and individually tested at the factory. Installation requires only hydraulic and electrical connections.
CONTROL SYSTEM
The user interface is a wired remote controller (5-wire connection, maximum length 50 m) with a 12-language menu. It allows the management of the following functions:
HEATING AND COOLING SYSTEMS
Where the heat pump is the sole energy source. In heating or cooling mode, the unit modulates compressor frequency to maintain the water temperature at the setpoint defined by the controller. The remote controller can also be configured to function as a room thermostat (e.g. for single-zone systems).
DOMESTIC HOT WATER (DHW) PRODUCTION
In DHW mode, the unit maintains the temperature of an external storage tank (not included) at the setpoint value. A 3-way diverter valve (not included) and a temperature sensor (T5 probe, L=10 m, included) are required for installation in the DHW tank well.
ADDITIONAL ENERGY SOURCES (boiler or electric heater)
These can be activated in Integration or Replacement mode based on set parameters when the system is operating in heating or DHW mode. The control board also activates auxiliary sources in case the heat pump is unavailable.
DHW TANK ELECTRIC HEATER
In DHW mode, the unit can manage an electric heater installed in the storage tank, used for integration, anti-legionella function, or as a backup energy source when the heat pump is inactive.
FAST DHW MODE
This manually activated function prioritizes DHW production by engaging all available energy sources (heat pump, electric heater, boiler) to quickly bring the DHW tank to the set temperature.
ANTI-LEGIONELLA FUNCTION
Weekly cycles can be scheduled via the controller. Proper execution requires integration with a DHW electric heater or boiler.
SILENT MODE
When enabled, it reduces the compressor frequency and fan speed to lower sound emissions and power consumption. Two levels are available, and a daily schedule can be programmed (e.g. at night).
ON/OFF VIA EXTERNAL CONTACT
The unit can be switched on and off via an external contact (e.g. room thermostat or remote switch). It will operate according to the mode set on the controller.
HEATING/COOLING VIA EXTERNAL CONTACTS
The unit can switch between heating and cooling via two external contacts (e.g. zone thermostat managing heating/cooling demand or remote switch).
ECO Mode: Heating mode schedules and setpoints can be defined for energy-saving operation.
WEEKLY TIMER
A weekly schedule can be set with different operating modes (HEATING/COOLING/DHW) and related setpoints for each day and time slot.
FROST PROTECTION
Guaranteed down to -20°C outdoor air temperature via the electronic control board, which activates the plate heat exchanger’s built-in electric heater, the heat pump itself in heating mode, and an electric booster (if installed).
CASCADE CONTROL OF MULTIPLE UNITS
Up to 6 units can be managed in cascade (1 master, 5 slaves, even with different outputs) via a single controller connected to the master unit. The master unit can also be dedicated to DHW production. In case of a slave unit failure, the remaining units continue to operate normally.
MANAGEMENT OF UP TO 2 ZONES (1 mixed, 1 direct)
The system can manage the pumps (not included) of both zones and, for the mixed zone only, the mixing valve (not included) and a water flow temperature probe (available as an accessory).
PHOTOVOLTAIC INPUT AND SMART GRID INPUT
The unit features 2 digital inputs for photovoltaic system and smart grid integration:
Photovoltaic input closed: activates DHW mode at 70°C setpoint and switches on DHW tank electric heater (if available). The unit operates in heating/cooling mode normally.
Photovoltaic input open + Smart grid input closed: standard operation.
Photovoltaic input open + Smart grid input open: DHW mode is disabled; the unit can run in heating/cooling mode for a defined time (settable via parameter), then switches off.
OTHER FEATURES
CURRENT LIMIT SETTING via parameter
REMOTE CONTROL VIA APP (iOS and Android available)
DETAILED ERROR DIAGNOSTICS with alarm history
DISPLAY OF ALL OPERATING PARAMETERS
REFRIGERANT CIRCUIT
Housed in a compartment shielded from airflow for easier maintenance. It includes a Twin Rotary DC inverter compressor for optimal dynamic balance and reduced vibration, mounted on rubber antivibration supports and wrapped in double-layer sound-absorbing material.
It is also equipped with a crankcase oil heater. The circuit features a brazed stainless-steel plate heat exchanger with built-in antifreeze electric heater, bidirectional electronic expansion valve, 4-way reversing valve, DC brushless axial fans with safety grills, and a corrosion-resistant finned coil (copper tubes and hydrophilic aluminum fins).
Temperature probes and pressure transducers monitor the circuit, while high- and low-pressure switches provide protection.
All units feature variable-speed fan control for optimal operation at low ambient temperatures in cooling and high ambient temperatures in heating.
HYDRAULIC CIRCUIT
Also housed in a protected compartment for easier servicing. Includes a low-consumption electronic circulator with DC brushless motor (3-speed), water flow switch, automatic air vent, water pressure gauge, expansion vessel, safety valve, and Y-strainer (included, to be installed by technician).
The plate heat exchanger and all piping are thermally insulated to prevent condensation and minimize heat loss.
STANDARD ACCESSORIES
WATER TEMPERATURE SENSOR: Configurable for use as T1 / Tbt1 / Tbt2 / T5 / Tw2 / Tsolar (refer to installation manual)
RUBBER ANTIVIBRATION MOUNTS.
Further info from manufacturer on IDOLA M 3.2 22T-30T Lamborghini CaloreClima