Lamborghini CaloreClima IDOLA S 3.2 - Тепловой насос
This new range features an Outdoor Unit housing the core of the refrigeration circuit—from the compressor to the fan and air-side heat exchanger—connected via refrigerant piping to the Indoor Unit.
The Indoor Unit integrates the hydraulic side of the system, with all key components pre-installed, including a high-efficiency circulator and expansion vessel, ensuring fast, practical, and safe installation.
An electric backup heater is included as standard: 3 kW for single-phase models and 6 kW for three-phase models.
The split configuration offers a major advantage: it eliminates any risk of freezing—even in extreme outdoor temperatures (as low as -25°C)—and even in the event of a power outage. This resolves a key limitation of outdoor monobloc units, which rely solely on electric antifreeze heaters.
All units meet the most demanding year-round climate control requirements. They can deliver hot water up to 65°C, making them suitable for nearly all types of heating systems—underfloor, fan coil, or radiator—and for domestic hot water (DHW) production via an external storage tank.
This new Full Inverter approach modulates all three of the system’s main power-consuming components—compressor, fan, and pump—using advanced DC inverter technology. This enables precise thermal load tracking, delivering outstanding efficiency and significant energy savings for the user.
Moreover, Lamborghini CaloreClima’s Full Inverter concept minimizes current spikes at startup, avoiding electrical network surges and extending the lifespan of system components. With some of the quietest sound levels on the market, the system can operate as the sole heat generator or be integrated with other sources, such as a boiler (see our Factory-Made Hybrid solutions).
All units are equipped with a temperature probe for an external DHW tank (not supplied, to be installed by the technician), and an outdoor air temperature sensor pre-installed on the Outdoor Unit, enabling efficient climate control in both heating and cooling modes.
Optional warranty extension available up to 5 years.
CONTROL SYSTEM
The user interface features Capsense touch technology and a 2.8” graphic display, offering a simple and intuitive user experience. The onboard interface communicates seamlessly with the new Connect CRP smart control system, capable of managing up to 8 thermostats (7 Connect CRP Zones plus 1 Connect CRP with full programmable thermostat functionality), across 2 zones: one direct and one mixed. Main management features include:
MODBUS PROTOCOL
Enables smart control via external BMS (Building Management System).
HEATING AND COOLING
When the heat pump is the sole generator, Full Inverter modulation maintains the setpoints for both heating and cooling while optimizing energy consumption. Preloaded climate curve settings improve comfort and further reduce energy use.
DOMESTIC HOT WATER (DHW) PRODUCTION
When the DHW sensor (to be installed on an external tank, not supplied) detects a drop below the threshold, the system switches to DHW mode with a dedicated setpoint. A 3-way diverter valve is included as standard.
SMART GRID INPUT FROM PHOTOVOLTAIC AND GRID
The unit features 2 digital inputs for photovoltaic and grid integration. These Smart Grid contacts optimize energy use and reduce energy bills:
EVU contact signals when PV production is active. The heat pump raises the DHW setpoint to increase self-consumption—where the user gains the most.
SG contact signals high energy pricing (if supported by the grid provider). The heat pump then limits operation based on user-defined parameters.
For detailed configuration, refer to the user manuals.
REMOTE CONTROL VIA APP
Available for iOS and Android via the optional Connect CRP module.
ADDITIONAL FEATURES
DHW TANK ELECTRIC HEATER
In DHW mode, the unit manages an electric heater in the storage tank as a supplemental source, for anti-legionella protection, or as a backup in case of system fault.
FAST DHW FUNCTION
Gives priority to DHW production by activating all available energy sources to reach the DHW setpoint as quickly as possible.
ANTI-LEGIONELLA FUNCTION
Allows scheduling of weekly anti-legionella cycles. To ensure proper function, an electric heater or auxiliary boiler must be installed with the DHW tank.
SILENT MODE
When activated, reduces maximum compressor frequency and fan speed to lower noise levels. Two levels are available and can be programmed into daily time slots (e.g. nighttime use).
ON/OFF VIA EXTERNAL CONTACT
The unit can be switched on and off via an external contact (e.g. zone thermostat). In this case, it operates in accordance with the controller’s settings.
HEATING/COOLING SWITCHING VIA EXTERNAL CONTACT
The system can receive an external summer/winter mode signal (e.g. from a zone thermostat).
ECO MODE
A dedicated setpoint for Eco operation can be configured with daily time bands.
WEEKLY SCHEDULING
With the optional Connect CRP, users can program daily time bands for each day of the week, defining the desired mode (HEATING / COOLING / DHW) and corresponding setpoints.
FROST PROTECTION
The system runs in heating mode with the circulator ON and, if installed, an electric booster to ensure protection in sub-zero conditions.
Further info from manufacturer on IDOLA S 3.2 Lamborghini CaloreClima