Yestate Logo
Lamborghini CaloreClima IDOLA S 3.2 - Тепловой насос — 1
Lamborghini CaloreClima IDOLA S 3.2 - Тепловой насос — 2
Lamborghini CaloreClima IDOLA S 3.2 - Тепловой насос — 3
ОтоплениеLamborghini CaloreClima#Lamborghini CaloreClima#Idola#Heating and air-conditioning systems#Main air handling units#Heat pumps

Lamborghini CaloreClima IDOLA S 3.2 - Тепловой насос

This new range features an Outdoor Unit housing the core of the refrigeration circuit—from the compressor to the fan and air-side heat exchanger—connected via refrigerant piping to the Indoor Unit.‎ The Indoor Unit integrates the hydraulic side of the system, with all key components pre-installed, including a high-efficiency circulator and expansion vessel, ensuring fast, practical, and safe installation.‎ An electric backup heater is included as standard: 3 kW for single-phase models and 6 kW for three-phase models.‎ The split configuration offers a major advantage: it eliminates any risk of freezing—even in extreme outdoor temperatures (as low as -25°C)—and even in the event of a power outage.‎ This resolves a key limitation of outdoor monobloc units, which rely solely on electric antifreeze heaters.‎ All units meet the most demanding year-round climate control requirements.‎ They can deliver hot water up to 65°C, making them suitable for nearly all types of heating systems—underfloor, fan coil, or radiator—and for domestic hot water (DHW) production via an external storage tank.‎ This new Full Inverter approach modulates all three of the system’s main power-consuming components—compressor, fan, and pump—using advanced DC inverter technology.‎ This enables precise thermal load tracking, delivering outstanding efficiency and significant energy savings for the user.‎ Moreover, Lamborghini CaloreClima’s Full Inverter concept minimizes current spikes at startup, avoiding electrical network surges and extending the lifespan of system components.‎ With some of the quietest sound levels on the market, the system can operate as the sole heat generator or be integrated with other sources, such as a boiler (see our Factory-Made Hybrid solutions).‎ All units are equipped with a temperature probe for an external DHW tank (not supplied, to be installed by the technician), and an outdoor air temperature sensor pre-installed on the Outdoor Unit, enabling efficient climate control in both heating and cooling modes.‎ Optional warranty extension available up to 5 years.‎ CONTROL SYSTEM The user interface features Capsense touch technology and a 2.‎8” graphic display, offering a simple and intuitive user experience.‎ The onboard interface communicates seamlessly with the new Connect CRP smart control system, capable of managing up to 8 thermostats (7 Connect CRP Zones plus 1 Connect CRP with full programmable thermostat functionality), across 2 zones: one direct and one mixed.‎ Main management features include: MODBUS PROTOCOL Enables smart control via external BMS (Building Management System).‎ HEATING AND COOLING When the heat pump is the sole generator, Full Inverter modulation maintains the setpoints for both heating and cooling while optimizing energy consumption.‎ Preloaded climate curve settings improve comfort and further reduce energy use.‎ DOMESTIC HOT WATER (DHW) PRODUCTION When the DHW sensor (to be installed on an external tank, not supplied) detects a drop below the threshold, the system switches to DHW mode with a dedicated setpoint.‎ A 3-way diverter valve is included as standard.‎ SMART GRID INPUT FROM PHOTOVOLTAIC AND GRID The unit features 2 digital inputs for photovoltaic and grid integration.‎ These Smart Grid contacts optimize energy use and reduce energy bills: EVU contact signals when PV production is active.‎ The heat pump raises the DHW setpoint to increase self-consumption—where the user gains the most.‎ SG contact signals high energy pricing (if supported by the grid provider).‎ The heat pump then limits operation based on user-defined parameters.‎ For detailed configuration, refer to the user manuals.‎ REMOTE CONTROL VIA APP Available for iOS and Android via the optional Connect CRP module.‎ ADDITIONAL FEATURES DHW TANK ELECTRIC HEATER In DHW mode, the unit manages an electric heater in the storage tank as a supplemental source, for anti-legionella protection, or as a backup in case of system fault.‎ FAST DHW FUNCTION Gives priority to DHW production by activating all available energy sources to reach the DHW setpoint as quickly as possible.‎ ANTI-LEGIONELLA FUNCTION Allows scheduling of weekly anti-legionella cycles.‎ To ensure proper function, an electric heater or auxiliary boiler must be installed with the DHW tank.‎ SILENT MODE When activated, reduces maximum compressor frequency and fan speed to lower noise levels.‎ Two levels are available and can be programmed into daily time slots (e.‎g.‎ nighttime use).‎ ON/OFF VIA EXTERNAL CONTACT The unit can be switched on and off via an external contact (e.‎g.‎ zone thermostat).‎ In this case, it operates in accordance with the controller’s settings.‎ HEATING/COOLING SWITCHING VIA EXTERNAL CONTACT The system can receive an external summer/winter mode signal (e.‎g.‎ from a zone thermostat).‎ ECO MODE A dedicated setpoint for Eco operation can be configured with daily time bands.‎ WEEKLY SCHEDULING With the optional Connect CRP, users can program daily time bands for each day of the week, defining the desired mode (HEATING / COOLING / DHW) and corresponding setpoints.‎ FROST PROTECTION The system runs in heating mode with the circulator ON and, if installed, an electric booster to ensure protection in sub-zero conditions.‎ Further info from manufacturer on IDOLA S 3.2 Lamborghini CaloreClima
0
0

Из этой же категории

Еще от бренда Lamborghini CaloreClima